Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathreport.tex
242 lines (191 loc) · 13 KB
/
report.tex
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
\documentclass{article}
\usepackage{mathtools}
\usepackage[margin=0.5in]{geometry}
\usepackage{graphicx}
\usepackage{caption}
\usepackage{subcaption}
\usepackage{hyperref}
\usepackage{booktabs}
\usepackage{float}
\usepackage{multirow}
\setlength{\parindent}{0pt}
\graphicspath{ {./experiment/data/} }
\title{Edge Detection Evaluation of HEp-2 Cells in Fluorescent Images}
\author{Ossama Edbali - ID: 1466610}
\begin{document}
\maketitle
\section{Aim}
This study aims to analyse the results and efficacy of several edge detection algorithms
on HEp-2 cells.
The edge detection/segmentation algorithms used are: Otsu, Sobel, Roberts, Canny,
Canny using anisotropic diffusion,
Laplacian of Gaussian, Difference of Gaussians and dilate-erode method.
The evaluation of each method is carried by ROC curves, sensitivity-specificity variation graphs and correspondence analysis.
\textbf{All the Matlab code and full data can be found here: \url{http://uobcs.github.io/hep2-edge-detection/}.}
\section{Method}
First of all the experiments where conducted using three main scripts (one for each
image):
\verb|x9343AM_task|, \verb|x10905JL_task| and \verb|x43590AM_task|.
Each script loads the relative image and true edge image. Then produces a greyscale image using the \texttt{rgb2gray} Matlab function.
Finally, it performs all the edge detection algorithms described above (delegating
to the class \texttt{EdgeDetection.m}).
A pre-analysis (qualitative) of the input has been carried out using the
background approximation image as a surface to see where illumination varies (using \verb|show_background| function).
It can be seen that the various input images are the outcome of different fluorescence patterns on the HEp-2 cells.
For all edge detectors there is a method inside the \texttt{EdgeDetection} class
as well as methods for generating the ROC space and specificity and sensitivity
in function of some parameters (e.g. threshold, sigma, number of iterations).
For Roberts and Sobel a function \verb|detect_edges(img, filterX, filterY)| was developed which convolves \verb|img| with the two filters and uses
\verb|magnitude| to produce the final result (before thresholding).
In regards to LoG, Gaussian smoothing was performed using \verb|gaussian_smoothing(image, sigma)|. Then convolve the smoothed image with the laplacian
operator and finally find the zero crossings using \verb|edge(res, 'zerocross')|.
\subsection*{Otsu's method}
One of the algorithms used in this study is Otsu's algorithm.
The aim is to find the threshold value where the sum of foreground and background spreads is at its minimum. First of all I calculate the weighted mean and variance
for both the background and foreground ($\mu_b$, $\sigma_b^2$ and
$\mu_f$, $\sigma_f^2$). Then I compute the \textbf{within-class variance} (two variances multiplied by their associated weights): $\sigma_W^2 = W_b \sigma_b^2+W_f \sigma_f^2$. I do the same calculation for candidate thresholds and the one that has the lowest within-class variance will be chosen. This algorithm is implemented in Matlab's
\verb|graythresh|. This will produce a binary image which edges' can be detected
easily by any of the edge detectors (Sobel in the experiment).
\subsection*{Dilate-erode method}
The dilate-erode method is a 4-step algorithm that uses a combination of morphological operators before using Sobel edge detector. The reason why this method
has been used is that when Sobel (or Roberts) is performed on the greyscale image, there are some lines of high contrast surrounding
the actual edge (like noise). The gaps between these small lines and the actual edge
can be filled using a \textbf{dilate morphological operator} (or non-linear neighbourhood
operator) with a structuring element (from the \verb|strel| function). Then
\verb|imfill| has been used to fill the holes inside the cell - this step can
be skipped but it will result in a lower performance.
The next step is to "reduce" the cell to get it back to its state before
dilation using
the \textbf{erosion} operator. Finally the Sobel filter has been used to detect
edges.
There are various ways to create the morphological operators. Here is the one
used in this study (erode example using a 5x5 mask): \verb|erode = @(x) min(x(:)); out = nlfilter(in,[5 5],erode)|.
\subsection*{Canny with anisotropic diffusion (CAD)}
From the study it has been noted that Canny performed with sensitivity lower than
0.4 in all input images. To enhance the images but still preserving true edges,
\textbf{anisotropic diffusion} has been used.
Anisotropic diffusion is a non-linear diffusion filtering for avoiding the
blurring problems of Gaussian smoothing (and others). It is an iterative
process to perform edge-preserving smoothing on the cells.
The algorithm is described mathematically as follows:
\begin{center}
$\frac{\partial}{\partial t}I(x, t) = \nabla \bullet (c(x, t) \nabla I(x, t))$
\end{center}
Here $t$ is the iteration step, $c(x, t)$ is a decreasing diffusion function
of the image gradient magnitude.
The \verb|anisodiff2D(im, num_iter, delta_t, kappa, option)| function in the codebase
has been implemented to accomplish anisotropic diffusion. Here \verb|im| is the
input image, \verb|num_iter| is the number of iterations, \verb|delta_t| is
the integration constant, \verb|kappa| is the diffusion constant and
\verb|option| defines which diffusion function to use.
\newline
I adopted three evaluation methods in order to assess the accuracy/efficacy of each edge
detector technique:
\subsection*{ROC curve}
The ROC curve has been used to detect which parameter to choose according
to a \textbf{diagnosis line} (in the experiment
(0, 1) to (1, 0) has been used). The implementation can be found under
the \verb|compute_roc(ID, IT)| function, where ID is the image
with detected edges and \verb|IT| is the image with true edges.
Basically it takes the two binary images and performs logical operations
for all possible cases (e.g. true positive, false positive etc\ldots) and
calculates the sum of "on" pixels in the resulting images. Then it combines
the results to find sensitivity and specificity:
\begin{center}
\verb|sensitivity = TP / (TP + FN)| and \verb|specificity = TN / (TN + FP);|
\end{center}
\subsection*{Sensitivity/Specificity variation}
This evaluation method simply uses the sensitivity and specificity parameters in function
of a variable (threshold, sigma, kappa or number of iterations). From this we
can see how different algorithms respond to the variation of some parameters.
This is implemented by the \verb|roc_params_comparison| static method in the
\verb|EdgeDetection| class.
\subsection*{Correspondence analysis (intra-method analysis)}
From $N$ edge detection results (using the same edge detector) test for
correspondence as follows: a pixel location identified as an edge by
all $N$ detector configurations (i.e. changing parameter)
will have the highest correspondence ($N$), and a
location identified as an edge by only one detector setup will have the lowest.
This is computed by the \verb|correspondence_analysis| function in the codebase which
adds all the input image matrices and, using Matlab's \verb|bar|, plots a bar diagram
with frequencies for each correspondence level (using \verb|histc|).
\section{Results}
A very interesting result is the comparison between Canny and Canny with anisotropic diffusion (using 9343 AM as a reference).
\begin{figure}[htp]
\centering
\includegraphics[width=.3\textwidth]{x9343AM/comparison.png}\hfill
\includegraphics[width=.3\textwidth]{x9343AM/canny/result.png}\hfill
\includegraphics[width=.3\textwidth]{x9343AM/cad/result_15_iterations.png}
\caption{(1) ROC space comparison, (2) Canny, (3) Canny with anisotropic diffusion }
\label{fig:figure3}
\end{figure}
It can be noted that Canny does not perform very well (sensitivity under 0.4).
However if we apply anisotropic diffusion,
sensitivity drastically increases (over 0.8). This happens because the input image
is very dark at the borders and Canny looses information in the smoothing
step as well as in the non-maximum suppression step. Supporting this statement
are the results of applying Canny to 43590 AM (which is very dark compared to
the other two images and therefore a high smoothing).
A summary of the whole data using the optimal parameters (\textbf{for the FULL evaluation graphs, tables and image results please visit this site: \url{http://uobcs.github.io/hep2-edge-detection/}}):
\begin{table}[H]
\centering
\caption{Overall results (1: 9343 AM, 2: 10905JL, 3: 43590AM)}
\label{my-label}
\begin{tabular}{|c|c|l|l|}
\hline
\multicolumn{1}{|l|}{Edge detector} & \multicolumn{1}{l|}{Image} & Sensitivity & Specificity \\ \hline
\multirow{3}{*}{Otsu} & 1 & 0.9225 & 0.9974 \\ \cline{2-4}
& 2 & 0.9279 & 0.9957 \\ \cline{2-4}
& 3 & 0.8813 & 0.9958 \\ \hline
\multirow{3}{*}{Sobel} & 1 & 0.8498 & 0.8638 \\ \cline{2-4}
& 2 & 0.8953 & 0.8852 \\ \cline{2-4}
& 3 & 0.8195 & 0.8237 \\ \hline
\multirow{3}{*}{Roberts} & 1 & 0.8477 & 0.8400 \\ \cline{2-4}
& 2 & 0.8646 & 0.8779 \\ \cline{2-4}
& 3 & 0.7540 & 0.8215 \\ \hline
\multirow{3}{*}{Canny} & 1 & 0.3404 & 0.9408 \\ \cline{2-4}
& 2 & 0.3057 & 0.9863 \\ \cline{2-4}
& 3 & 0.2396 & 0.9808 \\ \hline
\multirow{3}{*}{CAD} & 1 & 0.7910 & 0.86651 \\ \cline{2-4}
& 2 & 0.8139 & 0.9204 \\ \cline{2-4}
& 3 & 0.6734 & 0.8921 \\ \hline
\multirow{3}{*}{Dilate-Erode} & 1 & 0.8299 & 0.8058 \\ \cline{2-4}
& 2 & 0.8003 & 0.8119 \\ \cline{2-4}
& 3 & 0.7446 & 0.7863 \\ \hline
\multirow{3}{*}{LoG} & 1 & 0.2250 & 0.9419 \\ \cline{2-4}
& 2 & 0.2135 & 0.9324 \\ \cline{2-4}
& 3 & 0.1996 & 0.9207 \\ \hline
\multirow{3}{*}{DoG} & 1 & 0.2137 & 0.9857 \\ \cline{2-4}
& 2 & 0.2446 & 0.9941 \\ \cline{2-4}
& 3 & 0.17301 & 0.99094 \\ \hline
\end{tabular}
\end{table}
\begin{table}[H]
\centering
\caption{Otsu evaluation}
\label{otsu}
\begin{tabular}{@{}llll@{}}
\toprule
Image & Sensitivity & Specificity & Threshold \\ \midrule
9343 AM & 0.9225 & 0.9974 & 0.0902 \\
10905 JL & 0.9279 & 0.9957 & 0.1333 \\
43590 AM & 0.8813 & 0.9958 & 0.0510 \\ \bottomrule
\end{tabular}
\end{table}
Overall Otsu has proven to be the best choice in all the images. Although
computationally expensive, Otsu's method takes into account foreground and
background and gives satisfactory results only when the numbers of pixels in each class are close to each other (which is the case here).
Sobel and Roberts have performed almost equally in all images however Sobel has
higher specificity because it is less sensitive to isolated high intensity point variations. Thus it gives correct results when the edge do not exist in a given point.
In regards to the dilate-erode method
we can notice that the sensitivity decreases very fast compared to Sobel (or Roberts). This is because during the erode process some edges might be removed and this propagates to the Sobel edge detection and thresholding.
\section{Conclusion}
In this study various alternatives to the traditional edge detectors have been
tried because of their specific application to cell edge detection. For example
Canny is very sensitive to the fluorescence around the cells. LoG and DoG have
low sensitivity (for optimal parameters) because they highlight regions
of rapid intensity changes but the input images have gradual
change from the cell to the background (fluorescence effect). Some extensions to
the edge detectors (such as dilate-erode, adjust and anisotropic diffusion)
have proven to increase the efficacy of the edge detection.
\end{document}