Yep. Having the same issue once in a while, every couple of months or so. I normally just do a hard power off-on and it starts working again. I haven’t tried the reboot call but if that works it obviously is a better option. As I have the hard power off automatically programmed in my home automation system using a controllable wall plug I will just swap it to a reboot instead. Thanks for the tip. Mvh
|
Hi, I have seven units and the exact same problem. I use reboot as well. Every unit fail sometime, it's really a pain in the a**. I tried several wifi AP and fixed the IP but no luck. Nicolas Buanec |
Sounds strange but I'm a bit "glad" that I'm not the only one with this issue. |
All, FYI, Daikin released a new IOS app on 22nd of Feb 2016 (including a new FW release for the adapters 2.60). On of the items in the release notes states "WLAN Adapter: Improved Stability" |
Awesome! Let’s hope it keeps working. Now the only thing that I’m missing is starting “powerful” mode from the app/api...
|
The err= 255 or blinking power led has been solved with FW version 2.6.0. As with FW 2.2.5 only fix was to reboot your WLAN adapter. With the new FW, the API has also slightly changed, so it could be that your current programes dont work anymore. Regarding powerful mode, only units with PV: 3.2 or higher will support powerful (and econo) mode via the API. ( new 2016 R32 units). |
@dide0 thats some neat inside info 👍 (do you work at/for Daikin?) |
@mcalistair something like that ^^ |
@dide0 There are several variants of the adapters. I am using BRP072A42 for my models of fan coil. |
@mcalistair I saw that you are using BRP069A42 for a Ururu Sarara unit, what extra options do you have in the original app? Can you for instance see power consumption, humidify the air and set fan mode to silent? I just installed a BRP069A42 (that I bought on eBay) for my Ururu Sarara unit and can only see basic features in the Daikin Online Controller app and are afraid that I got a somewhat broken setup. |
No extra options:
So in other words I think its a limitation of the "early" type we have. It's not supported all those extra features. :( |
Sorry for hijacking the thread.. Ok, thank you @mcalistair, (I see that the current Sarara model comes with built-in WiFi,my unit is just 93 days old 😕 ). Will contact Daikin and see what they can do, as I can do all of the stuff via the remote control and it seems like it would be reasonable if the WiFi could do the same.. |
@fredrike As far as I remember, power consumption is only supported with the 2016+ R32 multi outdoor systems. I'll verify that |
@dide0 according to the Swedish site should the Ururu Sarara support both humidity settings and power consumption via the app.. https://www.daikin.se/sv_se/product-group/air-to-air-heat-pumps/r-serien/ururu_sarara.html |
@fredrike , I've did some checks and the unit your refering to has an "old" protocol version, which doesn't communicate Consumption ( if you check /common/basic_info it should advertise "pv = 0" ) |
I also have an Ururu Sarara ftxz (bought recently) . Unfortunately I saw that I have access only to very basic control of my unit . On-off ,temperature and Dide0 what you said about "old" protocol version means that there is no hope of controlling our Somewhere I saw a project to use an arduino to send IR commands emulating the original IR control Thank you |
Wanted to revive this thread and check if there are any updates on this project. Kudos to those who initiated it. I am as frustrated as any ururu sarara customer, I was shocked with how basic the online support of the adaptor is |
Hi @ael-code and other users,
First of all @ael-code thanks for all your work so far... Kudos.
@ All:
Since I got my 3 AP controllers:...
1x BRP069A42 for FTXR42EV1B9 (singe Ururu Sarara)
2x BRP069A43 for FTXS20K2V1B (dual split unit)
...I have "hangs/lockups" of the AP.
The time interval differs. Can be 1 week can be 3 weeks.
What happens is that the system will not react via the Daikin App and /common/basic_info will show err=255.
Since today I found the /common/reboot call. This fixes the issue for me. I'm very happy as before I had to switch the AP's to standalone and back before they start working again.
My Question to you all: Do you have the same issues?
My local reseller + Daikin Netherlands + Europe cannot fix it, so I'm very curious.
PS1 the strange thing is that the AP is still working and accessible via the API but cannot communicate with the AirconUnit itself.
PS2 I face the above issue with all 3 AP's at different times.