Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathsensors.yaml
executable file
·191 lines (166 loc) · 5.27 KB
/
sensors.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
- platform: nordpool
VAT: true
currency: "NOK"
price_in_cents: false
region: "Oslo"
precision: 3
price_type: kWh
- platform: systemmonitor
resources:
- type: memory_use
- type: memory_free
- type: load_1m
- type: load_5m
- type: load_15m
- type: processor_use
- type: processor_temperature
- platform: entur_public_transport
name: TogArnes
stop_ids:
- 'NSR:StopPlace:58868'
line_whitelist:
- 'NSB:Line:L14'
number_of_departures: 6
- platform: template
sensors:
dryer_on_time:
value_template: >
{{ (as_timestamp(now())
- state_attr('input_datetime.torketrommel_start', 'timestamp'))
|timestamp_custom('%H:%M:%S', false) }}
dryer_on_time_complete:
friendly_name: Dryer on Timer
value_template: >
{% if is_state('input_select.torketrommel_status', 'Tørker') %}
{{ states('sensor.dryer_on_time') }}
{% else %}
---
{% endif %}
- platform: template
sensors:
dryer_on:
value_template: "{{ states('sensor.torketrommel_power') | int > 5 }}"
- platform: template
sensors:
torketrommel:
friendly_name: "torketrommelkjorer"
value_template: >-
{% if is_state("sensor.dryer_on", "true") %}
Av
{% elif is_state("sensor.dryer_on", "false") %}
Torker
{% endif %}
icon_template: >-
{% if is_state("sensor.dryer_on", "true") %}
mdi:washing-machine
{% elif is_state("sensor.dryer_on", "false") %}
mdi:washing-machine-off
{% endif %}
- platform: hp_ilo
host: 192.168.1.12
name: mirai
username: Administrator
password: Password123!
monitored_variables:
- name: Inlet temperature
sensor_type: server_health
unit_of_measurement: "°C"
value_template: '{{ ilo_data.temperature["01-Inlet Ambient"].currentreading[0] }}'
- name: Server Health
sensor_type: server_health
value_template: '{{ ilo_data.health_at_a_glance }}'
- name: Server Power
sensor_type: server_power_readings
- platform: hp_ilo
host: vcflabilo.eirikzlab.local
username: Administrator
password: password
monitored_variables:
- name: Inlet temperature
sensor_type: server_health
unit_of_measurement: "°C"
value_template: '{{ ilo_data.temperature["01-Inlet Ambient"].currentreading[0] }}'
- name: Server Health
sensor_type: server_health
value_template: '{{ ilo_data.health_at_a_glance }}'
- name: Server Power
sensor_type: server_power_readings
- platform: hp_ilo
host: 192.168.250.34
name: Overste_lab
username: admin
password: Password123!
monitored_variables:
- name: Inlet temperature
sensor_type: server_health
unit_of_measurement: "°C"
value_template: '{{ ilo_data.temperature["01-Inlet Ambient"].currentreading[0] }}'
- name: Server Health
sensor_type: server_health
value_template: '{{ ilo_data.health_at_a_glance }}'
- name: Server Power
sensor_type: server_power_readings
- platform: hp_ilo
host: 192.168.250.31
name: Nederste_lab
username: admin
password: Password123!
monitored_variables:
- name: Inlet temperature
sensor_type: server_health
unit_of_measurement: "°C"
value_template: '{{ ilo_data.temperature["01-Inlet Ambient"].currentreading[0] }}'
- name: Server Health
sensor_type: server_health
value_template: '{{ ilo_data.health_at_a_glance }}'
- name: Server Power
sensor_type: server_power_readings
- platform: hp_ilo
host: 192.168.250.32
name: Nest_nederste_lab
username: admin
password: Password123!
monitored_variables:
- name: Inlet temperature
sensor_type: server_health
unit_of_measurement: "°C"
value_template: '{{ ilo_data.temperature["01-Inlet Ambient"].currentreading[0] }}'
- name: Server Health
sensor_type: server_health
value_template: '{{ ilo_data.health_at_a_glance }}'
- name: Server Power
sensor_type: server_power_readings
- platform: hp_ilo
host: 192.168.250.33
name: Nest_overste_lab
username: admin
password: Password123!
monitored_variables:
- name: Inlet temperature
sensor_type: server_health
unit_of_measurement: "°C"
value_template: '{{ ilo_data.temperature["01-Inlet Ambient"].currentreading[0] }}'
- name: Server Health
sensor_type: server_health
value_template: '{{ ilo_data.health_at_a_glance }}'
- name: Server Power
sensor_type: server_power_readings
- platform: integration
source: sensor.powerelwiz
unit_time: h
method: left
unique_id: tequieroputa
- platform: google_keep
username: !secret google_keep.username
password: !secret google_keep.password
labels:
- 'Middag'
pinned: true
- platform: snmp
host: 192.168.1.5
baseoid: 1.3.6.1.4.1.232.165.7.2.1.1.5.0
device_class: power
name: Rackstrøm
state_class: measurement
unit_of_measurement: W
version: "1"