Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathhost_status.go
183 lines (166 loc) · 7.3 KB
/
host_status.go
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
package hpmib
import (
"fmt"
"github.com/pkg/errors"
"github.com/soniah/gosnmp"
)
// OIDs defined by the HP MIB that each contain an integer describing the status of a sub-system.
// COMPONENT SUB-SYSTEM
// Processors (232.1.2.2.4:cpqSeCpuCondition)
// Memory (232.6.2.14.4:cpqHeResilientMemCondition)
// Cooling (232.6.2.6.4:cpqHeThermalSystemFanStatus)
// Sensors (232.6.2.6.3:cpqHeThermalTempStatus)
// Power (232.6.2.9.1:cpqHeFltTolPwrSupplyCondition)
// ProLiant Logs (232.6.2.11.2:cpqHeEventLogCondition)
// ASR (232.6.2.5.17:cpqHeAsrCondition)
// Drive Array (232.3.1.3:cpqDaMibCondition)
// SCSI (232.5.1.3:cpqScsiMibCondition)
// Storage Enclosures (232.8.1.3:cpqSsMibCondition)
// IDE (232.14.1.3:cpqIdeMibCondition)
// FC (232.16.1.3:cpqFcaMibCondition)
// Networks (232.18.1.3:cpqNicMibCondition)
// MP (232.9.1.3:cpqSm2MibCondition)
// HW/BIOS (232.6.2.16.1:cpqHeHWBiosCondition)
// Battery (232.6.2.17.1:cpqHeSysBackupBatteryCondition)
// iSCSI (232.169.1.3:cpqiScsiMibCondition)
const (
cpqHeAsrCondition OID = "1.3.6.1.4.1.232.6.2.5.17"
cpqHeSysBackupBatteryCondition OID = "1.3.6.1.4.1.232.6.2.17.1"
cpqDaCntlrOverallCondition OID = "1.3.6.1.4.1.232.3.2.2.1.1.6"
cpqDaMibCondition OID = "1.3.6.1.4.1.232.3.1.3"
cpqSsMibCondition OID = "1.3.6.1.4.1.232.8.1.3"
cpqHeThermalSystemFanStatus OID = "1.3.6.1.4.1.232.6.2.6.4"
cpqHeResilientMemCondition OID = "1.3.6.1.4.1.232.6.2.14.4"
cpqHeFltTolPwrSupplyCondition OID = "1.3.6.1.4.1.232.6.2.9.1"
cpqSeCPUCondition OID = "1.3.6.1.4.1.232.1.2.2.4"
cpqHeThermalTempStatus OID = "1.3.6.1.4.1.232.6.2.6.3"
cpqHePowerMeterCurrReading OID = "1.3.6.1.4.1.232.6.2.15.3"
)
// ASRStatus returns the status of the advanced server recovery sub-system.
// Returns a non-nil error if the status could not be determined.
func (m *MIB) ASRStatus() (Status, error) {
return getStatusSummary(m.snmpClient, cpqHeAsrCondition)
}
// BackupBatteryStatus returns the status of the battery backup sub-system.
// Returns a non-nil error if the status could not be determined.
func (m *MIB) BackupBatteryStatus() (Status, error) {
return getStatusSummary(m.snmpClient, cpqHeSysBackupBatteryCondition)
}
// ControllerStatus returns the overall status of the storage controllers.
// Returns a non-nil error if the status could not be determined.
func (m *MIB) ControllerStatus() (Status, error) {
return getStatusSummary(m.snmpClient, cpqDaCntlrOverallCondition)
}
// DriveArrayStatus returns the overall status of the drive arrays.
// Returns a non-nil error if the status could not be determined.
func (m *MIB) DriveArrayStatus() (Status, error) {
return getStatusSummary(m.snmpClient, cpqDaMibCondition)
}
// EnclosureStatus returns the overall status of the physical enclosure.
func (m *MIB) EnclosureStatus() (Status, error) {
return getStatusSummary(m.snmpClient, cpqSsMibCondition)
}
// FanStatus returns the status of the fan(s) in the system.
// Returns StatusOther if fan status detection is not supported by the system,
// StatusOK if all fans are operating properly, StatusDegraded if a non-required
// fan is not operating properly, or StatusFailed if a required fan is not operating properly.
// Returns a non-nil error if the status could not be determined.
func (m *MIB) FanStatus() (Status, error) {
return getStatusSummary(m.snmpClient, cpqHeThermalSystemFanStatus)
}
// MemoryStatus returns the status of the advanced memory protection sub-system.
// Returns a non-nil error if the status could not be determined.
func (m *MIB) MemoryStatus() (Status, error) {
return getStatusSummary(m.snmpClient, cpqHeResilientMemCondition)
}
// PowerSupplyStatus returns the status of the fault tolerant power supply sub-system.
// Returns StatusOther if power supply status detection is not supported by the system,
// StatusOK if all power supplies are operating properly, StatusDegraded if one or more
// power supplies are operating in a degraded state, or StatusFailed if one or more power
// supplies have failed.
// Returns a non-nil error if the status could not be determined.
func (m *MIB) PowerSupplyStatus() (Status, error) {
return getStatusSummary(m.snmpClient, cpqHeFltTolPwrSupplyCondition)
}
// PowerMeterReading returns the current power meter reading in Watts.
// Returns -1 if power meter is not supported by the server or an error
// if the power meter reading could not be determined.
func (m *MIB) PowerMeterReading() (int, error) {
res, err := m.snmpClient.GetNext([]string{string(cpqHePowerMeterCurrReading)})
if err != nil {
return -1, err
}
if len(res.Variables) == 0 {
return -1, ErrNoResultsReturned
}
if res.Variables[0].Type != gosnmp.Integer {
return -1, ErrExpectedInteger
}
watts := res.Variables[0].Value.(int)
return watts, nil
}
// ProcessorStatus returns the status of the processor sub-system.
// Returns a non-nil error if the status could not be determined.
func (m *MIB) ProcessorStatus() (Status, error) {
return getStatusSummary(m.snmpClient, cpqSeCPUCondition)
}
// TemperatureSensorStatus returns the status of the system's temperature sensors.
// Returns StatusOther if temperature sensor status detection is not supported by the system,
// StatusOK if all temperature sensors are within normal operating range, StatusDegraded if one
// or more temperature sensors are outside a normal operating range, or StatusFailed if one or
// more temperature sensors detect a condition that could permanently damage the system.
// Returns a non-nil error if the status could not be determined.
func (m *MIB) TemperatureSensorStatus() (Status, error) {
return getStatusSummary(m.snmpClient, cpqHeThermalTempStatus)
}
// getStatusSummary fetches the provided OID defined by the MIB whose value is expected to contain an
// integer that describes the overall status of a sub-system.
func getStatusSummary(client *gosnmp.GoSNMP, oid OID) (Status, error) {
res, err := client.GetNext([]string{string(oid)})
if err != nil {
return StatusUnknown, err
}
if res.Error == gosnmp.NoSuchName {
return StatusUnknown, fmt.Errorf("OID %s not found", oid.String())
}
if len(res.Variables) != 1 {
return StatusUnknown, fmt.Errorf("expected only 1 variable in response but got %d", len(res.Variables))
}
if res.Variables[0].Type == gosnmp.NoSuchObject || res.Variables[0].Type == gosnmp.NoSuchInstance {
return StatusOther, nil
}
if res.Variables[0].Type != gosnmp.Integer {
return StatusUnknown, errors.New("expected variable type to be an integer")
}
return parseStatus(fmt.Sprintf("%v", res.Variables[0].Value)), nil
}
// parseStatus takes an SNMP value and determines the status as defined by the HP MIB.
func parseStatus(s string) Status {
switch s {
case "1":
return StatusOther
case "2":
return StatusOK
case "3":
return StatusDegraded
case "4":
return StatusFailed
default:
return StatusUnknown
}
}
// String converts the Status to a human readable string.
func (s *Status) String() string {
switch *s {
case StatusOther:
return "Other"
case StatusOK:
return "OK"
case StatusDegraded:
return "Degraded"
case StatusFailed:
return "Failed"
default:
return "Unknown"
}
}