# Configuration file for pwmfan
# Commented values are used by default. Uncomment them to make changes.
# If not zero, enable verbose logging
#verbose=0
# If not zero, never actually touch the PWM device
#dry=0
# If not zero, enter degrees in fahrenheit instead of celsius
#fahrenheit=0
# Lower temperature limit
#mintemp=50 #C, or 122F
# Upper temperature limit
#maxtemp=75 #C, or 167F
# Disable fan at this many degrees below the lower temperature limit
#hysteresis=5 #C, or 9F
# Lower duty cycle in percents
#minduty=60
# Upper duty cycle in percents
#maxduty=100
# When fan changes from disabled to enabled, start with this duty cycle
#startduty=80
# for this many seconds
#starttime=1
# Interval between check cycles, in seconds
#interval=5
# On start up, enable the fan for the given number of seconds
#spin=0
# If not zero, keep fan spinning at the lower duty cycle limit instead of disabling
#idle=0
# PWM period in nanoseconds
#period=40000
# PWM chip number of the fan driver
#pwmchip=0
# PWM device number of the fan driver
#pwm=0