Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathp51TempControl.lua
136 lines (118 loc) · 3.94 KB
/
p51TempControl.lua
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
--[[
TODOS
- Determine target coolant temp for wep
- Determine target oil temp for wep
]]--
TARGET_AIRCRAFT = "51D"
THIS_AIRCRAFT = hub.getSimString("MetadataStart/_ACFT_NAME")
NEUTRAL = "0"
CLOSE = "1"
AUTO = "2"
OPEN = "3"
COMFORT_ZONE_PCT = .01 -- tolerance for target temp
MP = {}
-- mapping of sim to gauge values
MP.SIM_MIN = 4889
MP.SIM_MAX = 57499
MP.GUA_MIN = 15
MP.GUA_MAX = 67
MP.MAX_CONT = 50 -- above this number is MIL
MP.RED_LINE = 61 -- above this MP is WEP
MP.POWER = "NONE" -- used for debugging
MP.VALUE = "P-51D/MANIFOLD_PRESSURE"
OIL = {}
-- mapping of sim to gauge values
OIL.SIM_MIN = 13646
OIL.SIM_MAX = 64965
OIL.GUA_MIN = 40
OIL.GUA_MAX = 100
OIL.NORM = 75 -- target oil temp below mil
OIL.MIL = 90 -- redline = 90
OIL.WEP = 90 -- max = 100
OIL.TEMP = "P-51D/OIL_TEMP"
OIL.CONTROL = "OIL_CONTROL"
OIL.COVER = "OIL_CONTROL_COVER"
OIL.MSG = "oil NONE" -- used for debugging
hub.sendSimCommand(OIL.COVER, "1") -- open the oil switch cover
COOL = {}
-- mapping of sim to gauge values
COOL.SIM_MIN = 23166
COOL.SIM_MAX = 57124
COOL.GUA_MIN = 0
COOL.GUA_MAX = 120
COOL.NORM = 105 -- target coolant temp below mil
COOL.MIL = 120 -- target coolant temp in mil, redline = 120
COOL.WEP = 145 -- target coolant temp in wep, max = 150
COOL.TEMP = "P-51D/COOLANT_TEMP"
COOL.CONTROL = "COOLANT_CONTROL"
COOL.COVER = "COOLANT_CONTROL_COVER"
COOL.MSG = "coolant NONE" -- used for debugging
hub.sendSimCommand(COOL.COVER, "1") -- open coolant door sw cover
MESSAGE = "NONE"
hub.registerOutputCallback(function()
if string.find(THIS_AIRCRAFT, TARGET_AIRCRAFT) then
-- get the target oil temp for this mp power setting
oil_target_temp = getTargetTemp(OIL.NORM, OIL.MIL, OIL.WEP)
-- set the oil switch
OIL.MSG = setSwitch(getOilTemp(), OIL.CONTROL, oil_target_temp)
-- get the target coolant temp for this mp power setting
cool_target_temp = getTargetTemp(COOL.NORM, COOL.MIL, COOL.WEP)
-- set the coolant switch
COOL.MSG = setSwitch(getCoolTemp(), COOL.CONTROL, cool_target_temp)
end
end)
-- get a gauge output value (120) for a given sim input (75000)
function map(sim_val, sim_min, sim_max, gau_min, gau_max)
MESSAGE = gau_min
return math.floor((sim_val - sim_min) * (gau_max - gau_min) / (sim_max - sim_min) + gau_min)
end
-- get manifold pressure in inches
function getMp()
return map(hub.getSimInteger(MP.VALUE), MP.SIM_MIN, MP.SIM_MAX, MP.GUA_MIN, MP.GUA_MAX)
end
-- get oil temp in degrees
function getOilTemp()
return map(hub.getSimInteger(OIL.TEMP), OIL.SIM_MIN, OIL.SIM_MAX, OIL.GUA_MIN, OIL.GUA_MAX)
end
-- get coolant temp in degrees
function getCoolTemp()
return map(hub.getSimInteger(COOL.TEMP), COOL.SIM_MIN, COOL.SIM_MAX, COOL.GUA_MIN, COOL.GUA_MAX)
end
-- get the target temp for a current mp pressure
function getTargetTemp(norm_temp, mil_temp, wep_temp)
mp = getMp()
if mp > MP.MAX_CONT and mp < MP.RED_LINE then
-- mil power, set temps to mil
MP.POWER = "MIL"
return mil_temp
elseif mp >= MP.RED_LINE then
-- wep, set temps to max
MP.POWER = "WEP"
return wep_temp
end
-- normal ops
MP.POWER = "NORM"
return norm_temp
end
-- set temp control switch to position required to maintain temp
function setSwitch(temp, control, target)
-- determine low range of comfort zone
low = target * (1 - COMFORT_ZONE_PCT)
-- determine high range of comfort zone
high = target * (1 + COMFORT_ZONE_PCT)
-- get the current switch position, so that we dont have to update position every loop
curr_switch = hub.getSimInteger(control)
-- debug
message = "temp: " .. tostring(temp) .. ", target: " .. target -- .. ", low: " .. low .. ", high: " .. high
if temp < low then
-- temp is below target temp... close the control
hub.sendSimCommand(control, CLOSE)
return message .. ", door: closing."
elseif temp > high then
-- temp is above the target temp... open the control
hub.sendSimCommand(control, OPEN)
return message .. ", door: opening."
end
hub.sendSimCommand(control, NEUTRAL)
return message .. ", door: neutral."
end