Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

90.1 PRM heat pump data #40

Merged
merged 4 commits into from
Feb 28, 2024
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view

Large diffs are not rendered by default.

Large diffs are not rendered by default.

Large diffs are not rendered by default.

Large diffs are not rendered by default.

Large diffs are not rendered by default.

Large diffs are not rendered by default.

Large diffs are not rendered by default.

2 changes: 2 additions & 0 deletions building_energy_standards_data/database_tables/__init__.py
Original file line number Diff line number Diff line change
Expand Up @@ -22,7 +22,9 @@
"hvac_minimum_requirement_unitary_air_conditioners_90_1_prm",
"hvac_minimum_requirement_unitary_air_conditioners_IECC",
"hvac_minimum_requirement_heat_pump_cooling_90_1",
"hvac_minimum_requirement_heat_pump_cooling_90_1_prm",
"hvac_minimum_requirement_heat_pump_heating_90_1",
"hvac_minimum_requirement_heat_pump_heating_90_1_prm",
"hvac_minimum_requirement_chillers_90_1",
"hvac_minimum_requirement_chillers_90_1_prm",
"hvac_minimum_requirement_chillers_IECC",
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -7,98 +7,114 @@
RECORD_HELP = """
Must provide a tuple that contains:
template: TEXT
equipment_type: TEXT
cooling_type: TEXT
configuration: TEXT
heating_type: TEXT
subcategory: TEXT
application: TEXT
electric_power_phase: NUMERIC
region: TEXT
minimum_capacity: NUMERIC
maximum_capacity: NUMERIC
start_date: TEXT
end_date: TEXT
minimum_seasonal_efficiency: NUMERIC
minimum_full_load_efficiency: NUMERIC
minimum_iplv: NUMERIC
minimum_seasonal_energy_efficiency_ratio: NUMERIC
minimum_seasonal_energy_efficiency_ratio_2: NUMERIC
minimum_energy_efficiency_ratio: NUMERIC
minimum_integrated_part_load_value: NUMERIC
minimum_integrated_energy_efficiency_ratio: NUMERIC
minimum_combined_energy_efficiency_ratio: NUMERIC
pthp_eer_coefficient_1: NUMERIC
pthp_eer_coefficient_2: NUMERIC
cool_cap_ft: TEXT
cool_cap_fflow: TEXT
cool_eir_ft: TEXT
cool_eir_fflow: TEXT
cool_plf_fplr: TEXT
off_mode_power: NUMERIC
minimum_coefficient_of_performance_no_fan_cooling: NUMERIC
annotation: TEXT (optional)
"""

CREATE_HVAC_REQUIREMENT_HEAT_PUMP_COOLING_TABLE = """
CREATE TABLE IF NOT EXISTS %s
(id INTEGER PRIMARY KEY,
template TEXT NOT NULL,
equipment_type TEXT NOT NULL,
cooling_type TEXT NOT NULL,
heating_type TEXT NOT NULL,
subcategory TEXT NOT NULL,
heating_type TEXT,
configuration TEXT,
subcategory TEXT,
application TEXT,
electric_power_phase NUMERIC,
region TEXT,
minimum_capacity NUMERIC,
maximum_capacity NUMERIC,
start_date TEXT,
end_date TEXT,
minimum_seasonal_efficiency NUMERIC,
minimum_full_load_efficiency NUMERIC,
minimum_iplv NUMERIC,
minimum_seasonal_energy_efficiency_ratio NUMERIC,
minimum_seasonal_energy_efficiency_ratio_2 NUMERIC,
minimum_energy_efficiency_ratio NUMERIC,
minimum_integrated_part_load_value NUMERIC,
minimum_integrated_energy_efficiency_ratio NUMERIC,
minimum_combined_energy_efficiency_ratio NUMERIC,
pthp_eer_coefficient_1 NUMERIC,
pthp_eer_coefficient_2 NUMERIC,
cool_cap_ft TEXT,
cool_cap_fflow TEXT,
cool_eir_ft TEXT,
cool_eir_fflow TEXT,
cool_plf_fplr TEXT,
off_mode_power NUMERIC,
minimum_coefficient_of_performance_no_fan_cooling NUMERIC,
annotation TEXT);
"""

INSERT_A_HEAT_PUMP_COOLING_RECORD = """
INSERT INTO %s (
template,
equipment_type,
cooling_type,
heating_type,
configuration,
subcategory,
application,
electric_power_phase,
region,
minimum_capacity,
maximum_capacity,
start_date,
end_date,
minimum_seasonal_efficiency,
minimum_full_load_efficiency,
minimum_iplv,
minimum_seasonal_energy_efficiency_ratio,
minimum_seasonal_energy_efficiency_ratio_2,
minimum_energy_efficiency_ratio,
minimum_integrated_part_load_value,
minimum_integrated_energy_efficiency_ratio,
minimum_combined_energy_efficiency_ratio,
pthp_eer_coefficient_1,
pthp_eer_coefficient_2,
cool_cap_ft,
cool_cap_fflow,
cool_eir_ft,
cool_eir_fflow,
cool_plf_fplr,
off_mode_power,
minimum_coefficient_of_performance_no_fan_cooling,
annotation
)
VALUES (?, ?, ?, ? ,? , ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?);
VALUES (?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?);
"""

RECORD_TEMPLATE = {
"template": "",
"equipment_type": "",
"cooling_type": "",
"heating_type": "",
"configuration": "",
"subcategory": "",
"application": "",
"electric_power_phase": 0.0,
"region": "",
"minimum_capacity": 0.0,
"maximum_capacity": 0.0,
"start_date": "",
"end_date": "",
"minimum_seasonal_efficiency": 0.0,
"minimum_full_load_efficiency": 0.0,
"minimum_iplv": 0.0,
"minimum_seasonal_energy_efficiency_ratio": 0.0,
"minimum_seasonal_energy_efficiency_ratio_2": 0.0,
"minimum_energy_efficiency_ratio": 0.0,
"minimum_integrated_part_load_value": 0.0,
"minimum_integrated_energy_efficiency_ratio": 0.0,
"minimum_combined_energy_efficiency_ratio": 0.0,
"pthp_eer_coefficient_1": 0.0,
"pthp_eer_coefficient_2": 0.0,
"cool_cap_ft": "",
"cool_cap_fflow": "",
"cool_eir_ft": "",
"cool_eir_fflow": "",
"cool_plf_fplr": "",
"off_mode_power": 0.0,
"minimum_coefficient_of_performance_no_fan_cooling": 0.0,
"annotation": "",
}

Expand All @@ -124,16 +140,15 @@ def get_record_info(self):
def validate_record_datatype(self, record):
str_expected = [
"template",
"equipment_type",
"cooling_type",
"heating_type",
"configuration",
"subcategory",
"application",
"region",
"start_date",
"end_date",
"cool_cap_ft",
"cool_cap_fflow",
"cool_eir_ft",
"cool_eir_fflow",
"cool_plf_fplr",
]

for f in str_expected:
Expand All @@ -143,14 +158,19 @@ def validate_record_datatype(self, record):
), f"{f} requires to be a string, instead got {record[f]}"

float_expected = [
"electric_power_phase",
"minimum_capacity",
"maximum_capacity",
"minimum_seasonal_efficiency",
"minimum_full_load_efficiency",
"minimum_iplv",
"minimum_seasonal_energy_efficiency_ratio",
"minimum_seasonal_energy_efficiency_ratio_2",
"minimum_energy_efficiency_ratio",
"minimum_integrated_part_load_value",
"minimum_integrated_energy_efficiency_ratio",
"minimum_combined_energy_efficiency_ratio",
"pthp_eer_coefficient_1",
"pthp_eer_coefficient_2",
"off_mode_power",
"minimum_coefficient_of_performance_no_fan_cooling",
]

for f in float_expected:
Expand All @@ -169,23 +189,27 @@ def _preprocess_record(self, record):

return (
getattr_either("template", record),
getattr_either("equipment_type", record),
getattr_either("cooling_type", record),
getattr_either("heating_type", record),
getattr_either("configuration", record),
getattr_either("subcategory", record),
getattr_either("application", record),
getattr_either("electric_power_phase", record),
getattr_either("region", record),
getattr_either("minimum_capacity", record),
getattr_either("maximum_capacity", record),
getattr_either("start_date", record),
getattr_either("end_date", record),
getattr_either("minimum_seasonal_efficiency", record),
getattr_either("minimum_full_load_efficiency", record),
getattr_either("minimum_iplv", record),
getattr_either("minimum_seasonal_energy_efficiency_ratio", record),
getattr_either("minimum_seasonal_energy_efficiency_ratio_2", record),
getattr_either("minimum_energy_efficiency_ratio", record),
getattr_either("minimum_integrated_part_load_value", record),
getattr_either("minimum_integrated_energy_efficiency_ratio", record),
getattr_either("minimum_combined_energy_efficiency_ratio", record),
getattr_either("pthp_eer_coefficient_1", record),
getattr_either("pthp_eer_coefficient_2", record),
getattr_either("cool_cap_ft", record),
getattr_either("cool_cap_fflow", record),
getattr_either("cool_eir_ft", record),
getattr_either("cool_eir_fflow", record),
getattr_either("cool_plf_fplr", record),
getattr_either("off_mode_power", record),
getattr_either("minimum_coefficient_of_performance_no_fan_cooling", record),
getattr_either("annotation", record),
)
Original file line number Diff line number Diff line change
@@ -0,0 +1,17 @@
import sqlite3

from building_energy_standards_data.database_tables.hvac_minimum_requirement_heat_pump_cooling import (
HVACMinimumRequirementHeatPumpCooling,
)

TABLE_NAME = "hvac_minimum_requirement_heat_pump_cooling_90_1_prm"


class HVACMinimumRequirementHeatPumpCooling901PRMTable(
HVACMinimumRequirementHeatPumpCooling
):
def __init__(self):
super(HVACMinimumRequirementHeatPumpCooling901PRMTable, self).__init__(
table_name=TABLE_NAME,
initial_data_directory=f"building_energy_standards_data/database_files/{TABLE_NAME}",
)
Loading
Loading